Performance of 97-elements ALPAO membrane magnetic deformable mirror in Adaptive Optics - Optical Coherence Tomography system for in vivo imaging of human retina

Authors

  • Robert J. Zawadzki UC Davis Eye Center
  • Steven M. Jones 2Lawrence Livermore National Laboratory
  • Sandra E. Balderas-Mata
  • Sylwia M. Maliszewska
  • Scot S. Olivier
  • John S. Werner

DOI:

https://doi.org/10.4302/photon.%20lett.%20pl.v3i4.264

Abstract

We present an evaluation of two different configurations of the ALPAO 97-actuator membrane magnetic deformable mirror for wavefront correction, using either 7 or 9 actuators across the eye pupil. These tests included monitoring of aberration correction for a human subject. This AO-sub system is part of the UC Davis high-resolution human retinal imaging adaptive optics - optical coherence tomography (AO-OCT) instrument. AO-OCT allows the three-dimensional (3D) visualization of different retinal structures in vivo with high volumetric resolution (3x3x3?m3).

Full Text: PDF

References:
  1. [1] R.J. Zawadzki, S. Jones, S. Olivier, M. Zhao, B. Bower, J. Izatt, S. Choi, S. Laut, and J. Werner, "Adaptive-optics optical coherence tomography for high-resolution and high-speed 3D retinal in vivo imaging", Opt. Exp. 13, 8532 (2005), [CrossRef]
  2. [2] R.J. Zawadzki, B. Cense, Y. Zhang, S.S. Choi, D.T. Miller, and J.S. Werner, "Ultrahigh-resolution optical coherence tomography with monochromatic and chromatic aberration correction", Opt. Exp. 16, 8126 (2008), [CrossRef]
  3. [3] R.J. Zawadzki, S.M. Jones, S. Pilli, S. Balderas-Mata, D. Kim, S.S. Olivier, and J.S. Werner, "Integrated adaptive optics optical coherence tomography and adaptive optics scanning laser ophthalmoscope system for simultaneous cellular resolution in vivo retinal imaging", Biomed. Opt. Exp. 2, 1674 (2011), [CrossRef]
  4. [4] J. Liang, D.R. Williams and D.T. Miller, "Supernormal vision and high-resolution retinal imaging through adaptive optics", J. Opt. Soc. Am. A 14, 2884 (1997), [CrossRef]
  5. [5] A. Roorda, F. Romero-Borja, W.J. Donnelly III, H. Queener, T.J. Hebert, and M.C.W. Campbell, "Adaptive optics scanning laser ophthalmoscopy", Opt. Exp. 10, 405 (2002), [DirectLink]
  6. D. Huang, E. A. Swanson, C.P. Lin, J.S. Schuman, W.G. Stinson, W. Chang, M.R. Flotte, K. Gregory, C.A. Puliafito, "Optical coherence tomography", Science 254, 1178 (1991). [CrossRef]
  7. W. Drexler and J.G. Fujimoto, "Optical Coherence Tomography in Ophthalmology", J. Biomed. Opt. 12, 041201 (2007). [CrossRef]
  8. [8] M. Wojtkowski, "High-speed optical coherence tomography: basics and applications", Applied Optics 49, D30 (2010), [CrossRef]
  9. D.A. Horsley, H. Park, S.P. Laut and J.S. Werner, "Characterization of a bimorph deformable mirror using stroboscopic phase-shifting interferometry", Sensors and Actuators A: Physical 134, 221 (2007). [CrossRef]
  10. J.W. Evans, R.J. Zawadzki, S.M. Jones, S.S. Olivier, and J.S. Werner, "Error budget analysis for an Adaptive Optics Optical Coherence Tomography System", Opt. Exp. 17, 13768 (2009), [CrossRef]
  11. N. Doble, D.T. Miller, G. Yoon, and D.R. Williams, "Requirements for discrete actuator and segmented wavefront correctors for aberration compensation in two large populations of human eyes", Appl. Opt. 46, 4501 (2007), [CrossRef]
  12. N. Devaney, E. Dalimier, T. Farrell, D. Coburn, R. Mackey, D. Mackey, F. Laurent, E. Daly, and C. Dainty, "Correction of ocular and atmospheric wavefronts: a comparison of the performance of various deformable mirrors", Appl. Opt. 47, 6550 [CrossRef]

Downloads

Published

2011-12-29

How to Cite

[1]
R. J. Zawadzki, S. M. Jones, S. E. Balderas-Mata, S. M. Maliszewska, S. S. Olivier, and J. S. Werner, “Performance of 97-elements ALPAO membrane magnetic deformable mirror in Adaptive Optics - Optical Coherence Tomography system for in vivo imaging of human retina”, Photonics Lett. Pol., vol. 3, no. 4, pp. pp. 147–149, Dec. 2011.

Issue

Section

Articles